Thông tin chi tiết sản phẩm:
|
| Nghị quyết: | 1 phần triệu | Thời gian trả lời (T90): | ≤ 19 giây |
|---|---|---|---|
| Nguyên tắc kỹ thuật: | Điện hóa | Nhiệt độ hoạt động: | -20oC đến +50oC |
| Phạm vi độ ẩm: | 15–95% RH | Tuổi thọ dự kiến: | 2 năm |
| Thiết bị tương thích: | Máy đo khí khu vực bán kính BZ1 | phương pháp giao diện: | Plug-and-play mô-đun SafeCore |
| Làm nổi bật: | Electrochemical CO gas sensor,0-1500PPM carbon monoxide detector,BZ1 area gas monitor |
||
Product Description:
YJJ 17156650-1 0-1500PPM Electrochemical Carbon Monoxide (CO) Gas Sensor for Radius BZ1 Area Gas Monitor
Features:
1. Core Parameters (Original Factory Specifications) Table
Parameter item Specification value
Brand / Model Industrial Scientific 17156650-1
Detected gas Carbon Monoxide (CO)
Measurement range 0–1500 ppm
Resolution 1 ppm
Response time (T90) ≤19 seconds (typical value)
Technical principle Electrochemical (DualSense™ dual sensing technology)
Operating temperature -20 ℃ ~ +50 ℃
Humidity range 15–95% RH (non-condensing)
Expected lifespan 2 years (in air, normal use)
Compatible equipment Radius BZ1 area gas monitor
Interface method SafeCore™ modular plug-and-play (plug and play, no on-site calibration required)
II. Core functions and application scenarios
The core function of this sensor is to monitor the leakage / concentration of carbon monoxide gas in industrial environments, and to provide safety alarms. The main application scenarios include:
Work in confined spaces
Tunnel construction, underground pipe galleries, sewage treatment plants, tank interior operations, etc., where CO is prone to accumulate, real-time monitoring of gas concentration to prevent personnel poisoning.
Industrial production sites
Petrochemicals, metallurgy, boiler rooms, internal combustion engine operation areas, etc., where CO is prone to be generated, used for environmental safety monitoring.
Emergency and area monitoring
Combined with Radius BZ1 detector, realize real-time monitoring of gas concentration in multiple areas and wireless networking at the site, data can be synchronized to the background, and achieve remote safety management.
Compliance testing
Meet the limit monitoring requirements of OSHA, China occupational health and safety, etc. for CO concentration in the workplace (such as 8-hour average limit 25 ppm, short-term exposure limit 100 ppm).
III. Key technical features
DualSense™ dual sensing technology
Simultaneously monitor gas signals and sensor health status, early warning of sensor aging, poisoning or failure, avoiding false alarms / missed alarms, significantly improving reliability.
SafeCore™ modular design
Standardized interfaces, support for quick plug-and-play replacement, no need for re-calibration after replacement, reducing maintenance costs and downtime.
Industrial-grade reliability
Anti-electromagnetic interference, anti-vibration, anti-corrosion, suitable for harsh environments in industrial sites.
Long lifespan and low maintenance
Design life of 2 years, high stability, small drift, reducing the need for frequent calibration.
Specifications:
| Gas detection | CO |
| Measurement range | 0-1500PPM |
| Resolution | 1 ppm |
| Response time (T90) | ≤19 seconds |
| Cold / Hot Temperature Resistance | 22 ± 3 Ω |
| Radiation Area | 11 mm |
![]()
Người liên hệ: Miss. Xu
Tel: 86+13352990255